Output Type: | Single |
---|---|
Warranty: | 1 Year |
Output Power: | 51 - 100W |
Input Voltage: | 110-220V |
Connection Mode: | Single Set Output |
Starting Mode: | Power Start LED Indicator |
Customization: |
---|
Suppliers with verified business licenses
75W single output switching power supply
peculiarity
1. International universal full range of exchange input
2. Withstand 300VAC surge input for 5 seconds
3. No-load power consumption < 0.5W
4. The working temperature can be up to 70ºC
5. Protection type: short circuit/over load/over voltage
6. Natural air cooling
7. High efficiency, high life and high reliability
8. Power start LED indicator
9. All 105ºC long-life electrolytic capacitors are used
10.100% full load aging test
11.1 3-year warranty
Industrial automation machinery, Industrial control systems, Mechanical and electrical equipment, electronic instruments, equipment and installations, household appliances
Model number | RS-75-3.3 | RS-75-5 | RS-75-12 | RS-75-15 | RS-75-24 | RS-75-48 | |
exportation | Output DC voltage | 3.3V | 5V | 12V | 15V | 24V | 48V |
Rated current | 15A | 12A | 6A | 5A | 3.2A | 1.6A | |
Current range | 0-15A | 0-12A | 0-6A | 0-5A | 0-3.2A | 0-1.6A | |
Rated power | 49.5W | 60W | 72W | 75W | 76.8W | 76.8W | |
Ripple and noise | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
Voltage regulation range | 3-3.6V | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | 22-27.6V | 42-54V | |
Voltage accuracy | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load adjustment rate | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Start and rise time | 500ms,30ms/230VAC 1200ms,30ms/115VAC(At full load) | ||||||
Holding time | 60ms/230VAC 14ms/115VAC(At full load) | ||||||
input | voltage range | 88-264VAC(Withstand 300VAC surge input 5S, no damage) | |||||
Frequency range | 47-63Hz | ||||||
Efficiency (Typ) | 75% | 79% | 85% | 86% | 89% | 90% | |
Alternating Current(Typ) | 2.5A/115VAC 1.5A/230AC | ||||||
Inrush current (Typ) | Cold start: 40A/230VAC | ||||||
Leakage current | <2mA/240VAC | ||||||
Protection | overvoltage | Rated output power 110%-150% | |||||
Protection mode: burp mode, automatically recovered after load anomalies are removed | |||||||
overvoltage | 3.8-4.45V | 5.75-6.75V | 13.8-16.2V | 17.25-20.25V | 27.6-32.4V | 55.2-64.8V | |
Protection mode: hiccup mode, the voltage abnormal condition can be automatically restored after removal | |||||||
secure | authentication | CE ROHS CCC | |||||
environment | environment | -25ºC~+70ºC | |||||
Working humidity | 20~90%RH,non-condensing | ||||||
Storage temperature and humidity | -4ºC~+85ºC,10~95%RH | ||||||
Temperature coefficient | ±0.03%/ºC (0ºC~50ºC) | ||||||
Vibration resistance | 10-500HZ 2G 10min/1 cycle, X, Y, Z axis 60 minutes each | ||||||
dimension |
129*97*38 mm |