Output Type: | Single |
---|---|
Warranty: | 1 Year |
Output Power: | 51 - 100W |
Input Voltage: | 110-220V |
Voltage Regulating Mode: | Frequency Modulation Type |
Power Supplying System: | Terminal Power Distribution Equipment |
Customization: |
---|
Suppliers with verified business licenses
100W single output switching power supply
peculiarity
1. Full range AC input
2. Withstand 300VAC surge input for 5 seconds
3. No-load power consumption < 0.2W
4. Small size, 1U low shape
5. The operating temperature can be up to 70ºC
6. Protection type: short circuit/over load/over voltage
7. Natural air cooling
8. High efficiency, high life and high reliability
9. Power start LED indicator
10.100% full load aging test
Industrial automation machinery, Industrial control systems, Mechanical and electrical equipment, electronic instruments, equipment and installations, household appliances
exportation | Model number | LRS-100-3.3 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 |
Dc voltage | 3.3V | 5V | 12V | 15V | 24V | 36V | 48V | |
Rated current | 20A | 18A | 8.5A | 7A | 4.5A | 2.8A | 2.3A | |
Current range | 0-20A | 0-18A | 0-8.5A | 0-7A | 0-4.5A | 0-2.8A | 0-2.3A | |
Rated power | 66W | 90W | 102W | 105W | 108W | 100.8W | 110.4W | |
Ripple and noise | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
Voltage regulation range | 2.97-3.6V | 4.5-5.5V | 10.2-13.8V | 13.5-18V | 21.6-28.8V | 32.4-39.6V | 43.2-52.8V | |
Voltage accuracy | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load adjustment rate | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Start and rise time | 500ms,30ms/230VAC 500ms,30ms/115VAC(full load) | |||||||
Holding time | 55ms/230VAC 10ms/115VAC(full load) | |||||||
input | Voltage range | 85-264VAC | ||||||
Frequency range | 47-63Hz | |||||||
Efficiency (Typ.) | 84.5% | 86.0% | 88.0% | 88.5% | 90.0% | 90.5.% | 91.0% | |
Alternating current(Typ.) | 1.9A/115VAC 1.2A/230VAC | |||||||
Inrush current (Typ.) | Cold start:50A/230VAC | |||||||
Leakage current | <0.75mA/240VAC | |||||||
Protection | Excess load | 110%-150% of rated output power | ||||||
Protected mode: hiccup mode, which automatically recovers after abnormal conditions are removed | ||||||||
overvoltage | 3.8-4.45V | 5.75-6.75V | 13.8-16.2V | 18.75-21.75V | 28.8-33.6V | 41.4-48.6V | 55.2-64.8V | |
Protection mode: The output voltage is turned off and the output voltage is restarted | ||||||||
Safety regulation | authentication | CE ROHS CCC | ||||||
environment | Operating temperature | -30ºC~+70ºC | ||||||
Working humidity | 20~90%RH,non-condensing | |||||||
Storage temperature and humidity | -40ºC~+85ºC,10~95%RH | |||||||
Temperature coefficient | ±0.03%/ºC (0ºC~50ºC) | |||||||
Vibration resistance | 10-500HZ 2G 10minutes/cycle,X, Y, Z axis 60 minutes each | |||||||
Overvoltage level | ||||||||
size |
129*97*30 mm |
Suppliers with verified business licenses