500W single output switching power supply
peculiarity
1. Full range AC input
2. Built-in active PFC function, PF>0.95
3.1U Low profile
4. Protection type: short circuit/over load/over voltage/over temperature
5. With fan on/off control
6. There is a DC fan for forced air cooling
7. High efficiency, high life and high reliability
8. Power start LED indicator
9.100% full load aging test
Industrial automation machinery, Industrial control systems, Mechanical and electrical equipment, electronic instruments, equipment and installations, household appliances
exportation | Model number | LRS-500-3.3 | LRS-500-5 | LRS-500-12 | LRS-500-15 | LRS-500-24 | LRS-500-48 |
Dc voltage | 3.3V | 5V | 12V | 15V | 24V | 48V | |
Rated current | 90A | 90A | 41.7A | 33.4A | 21A | 10.5A | |
Current range | 0-90A | 0-90A | 0-41.7A | 0-33.4A | 0-21A | 0-10.5A | |
Rated power | 297W | 450W | 500.4W | 501W | 504W | 504W | |
Ripple and noise | 120mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | |
Voltage regulation range | 2.8-3.6V | 4.5-5.5V | 10-13.2V | 13.5-18V | 20-26.4V | 41-56V | |
Voltage accuracy | ±2.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | |
Load adjustment rate | ±1.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Start and rise time | 1500ms,80ms/230VAC 3000ms,80ms/115VAC(full load) | ||||||
Holding time | 18ms/230VAC 14ms/115VAC(full load) | ||||||
input | Voltage range | 85-264VAC | |||||
Frequency range | 47-63Hz | ||||||
Power factor(Typ.) | PF>0.95/230VAC PF>0.98/115VAC (full load) | ||||||
Efficiency (Typ.) | 81.0% | 84.0% | 88.0% | 88.0% | 89.0% | 90.5% | |
Alternating current(Typ.) | 4.2A/115VAC 2.1A/230VAC | 5.3A/115 VAC 2.65A/230VAC |
|||||
Inrush current(Typ.) | 20A/115VAC 40A/230VAC | ||||||
Leakage current | <2.0mA/240VAC | ||||||
Protection | Excess load | 105%-135% of the rated output power | |||||
Protection mode: constant current limit, abnormal conditions can be automatically restored after removal | |||||||
overvoltage | 3.8-4.5V | 5.75-6.75V | 13.8-16.2V | 18.8-21.8V | 27.6-32.4V | 58.4-68V | |
Protection mode: The output voltage is turned off and recovered after restart | |||||||
Excess temperature | Protection mode: Turn off the output voltage and recover automatically after the temperature drops | ||||||
Feature | Fan control | RTH2≥50 ° C ±10 ° C The fan is on. RTH2≤40ºC±10ºC Fan off (3.3-5V fan is always working, 12-48V fan on/off control) | |||||
Safety regulation | authentication | CE ROHS CCC | |||||
environment | Operating temperature | -30ºC~+70ºC | |||||
Working humidity | 20~90%RH,non-condensing | ||||||
Storage temperature and humidity | -40ºC~+85ºC,10~95%RHnon-condensing | ||||||
Temperature coefficient | ±0.03%/ºC (0ºC~50ºC) | ||||||
Vibration resistance | 10-500HZ 2G 10Minutes/period,X, Y, Z axis 60 minutes each | ||||||